Paper
19 January 1984 The BAMM IIA Radiometer
R. T. Pohlman
Author Affiliations +
Abstract
The Balloon Altitude Mosaic Measurement (BAMM) IIA Radiometer is designed to make mosaic measurements in either of two modes of operation: the stare or demonstration mode and the radiometer mode. In the stare mode, background suppression and target detection can be demonstrated; in the radiometer mode the incoming energy is chopped to allow absolute measurements to be made. The Noise Equivalent Radiance (NER) in each available spectral band is less than 2.5E-8 W/cm2-sr in the stare mode and less than 1.25E-7 W/cm2-sr in the radiometer mode. The Radiometer is physically divided into two units: the Radiometer Unit and the Support Electronics Unit. The Radiometer Unit contains the optical, detection, and preprocessor sections of the instrument. Ten narrow-band spectral filters in the 2.59 to 5.1 micrometer region are mounted on a wheel and are selectable from the ground. Three telescopes on a turret allow the selection of 50, 200, or 800 meter detector footprints (at the nadir from the 100,000 ft. flight altitude). The focal plane module uses the Grumman-developed Z-dimension technology with 16 x 64 HgCdTe detectors. Included on the module are hybrid CMOS chips containing the signal conditioning circuitry for sample and hold operations, bandpass filtering, and 32:1 signal multiplexing. The second unit, the Support Electronics, supplies control signals, bias voltages, and clock signals. The output lines from the focal plane are converted to digital signals, multiplexed, and formatted for PCM trans-mission to the ground in this unit.
© (1984) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. T. Pohlman "The BAMM IIA Radiometer", Proc. SPIE 0430, Infrared Technology IX, (19 January 1984); https://doi.org/10.1117/12.936371
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Radiometry

Sensors

Telescopes

Optical filters

Electronics

Calibration

Black bodies

RELATED CONTENT

Characterization of a thermal-infrared field radiometer
Proceedings of SPIE (September 18 1997)
Pioneer-Venus Solar Flux Radiometer
Proceedings of SPIE (September 27 1979)
3D positioning germanium detectors for gamma-ray astronomy
Proceedings of SPIE (January 10 2003)
OPERA a small size concept for earth radiation budget...
Proceedings of SPIE (October 31 1996)
Next generation along track scanning radiometer - SLSTR
Proceedings of SPIE (October 23 2012)

Back to Top