Abstract
We describe how to expand the dynamical range of active triangulation systems. The method is based on the expansion of depth of focus, in order to achieve a larger measuring range - and on the reduction of coherent noise, in order to achieve better resolution of depth. With a 1024 element linear photodiode array we could achieve about 15000 resolvable depth positions, in preliminary experiments.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
W Dremel, G Hausler, and M Maul "Triangulation With Large Dynamical Range", Proc. SPIE 0665, Optical Techniques for Industrial Inspection, (23 October 1986); https://doi.org/10.1117/12.938742