Paper
25 July 1989 Proposed Injection Locking Of A Long Pulse Relativistic Magnetron
S. C. Chen, G. Bekefi, R. Temkin, C. de Graff
Author Affiliations +
Abstract
We report results of the initial operation of a 1μs relativistic magnetron system to be used in the phase locking experiment. Full voltage pulse length with no evidence of diode shorting due to plasma closure is achieved in smooth bore geometry. The operating characteristics of the 700 kV, 700 A modulator together with the computerized control/acquisition system for the phase locking experiment is also described.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S. C. Chen, G. Bekefi, R. Temkin, and C. de Graff "Proposed Injection Locking Of A Long Pulse Relativistic Magnetron", Proc. SPIE 1061, Microwave and Particle Beam Sources and Directed Energy Concepts, (25 July 1989); https://doi.org/10.1117/12.951793
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mode locking

Oscillators

Modulators

Diodes

Magnetism

Microwave radiation

Medium wave

RELATED CONTENT

Progress in development of high power gyrotrons
Proceedings of SPIE (August 30 1993)
Injection locking of a long-pulse relativistic magnetron
Proceedings of SPIE (April 01 1991)
Experiments on slotted coaxial high-power gyrotrons
Proceedings of SPIE (July 14 2000)
Relativistic Magnetron Research
Proceedings of SPIE (May 09 1988)

Back to Top