Paper
19 July 2000 Reticle inspection system using DUV wavelength and new alogorithm platform for advanced reticle inspection for 0.13-μm technology node
David S. Alles, Paul Terbeek, Shauh-Teh Juang, James N. Wiley, Kangmin Hsia
Author Affiliations +
Abstract
KLA-Tencor has developed a fourth-generation reticle inspection system, the KLA-Tencor 570, using DUV imaging to detect 100-nm defects on advanced OPC and PSM reticles for the 0.13 micron technology node production and 0.10 micron technology development. This system contains innovations in optics, electronics, mechanics, algorithms, and software. The DUV wavelength of the optical system improves the resolution and thus the minimum linewidth capability. A low- noise optical system generates high-quality images to improve productivity, facilitate defect classification, and reduce operator errors. The United Inspection Computer (UIC), a high-speed scalable computational engine, renders database data to create an image of the mask for die-to- database inspections. The UIC uses the new Ultra-Performance Algorithm, which provides high detection sensitivity at high speed for D:D and D:DB inspections. UPA can handle complex structures such as advanced OPC and phase shift mask. TI places no fundamental requirement on the size of OPC features. UPA classified defects automatically. The operator can select sensitivity settings independently for each defect type. Since UPA measures the CD of every feature on the reticle, it can also make total plate quality measurements for statistical process control of mask manufacturing. A new reticle handling system reduces overhead time and allows easy loading and unloading of the reticle. This system manipulates 6-inch and 230-mm reticles with and without pellicles. A flexible adapter design allows the system to mix different reticle sizes. A new data preparation system executes on a multi-processor computer with a 64-bit operating system to minimize data preparation time. This DPS architecture allows the operator to change various inspection parameters such as pixel size, alignment points, DNIR's and rotation without the need for re-prep, thereby improving productivity and flexibility. The KLA- Tencor 570 also allows optional remote Data Prep. Test results indicate that the KLA-Tencor 570 already meets its sensitivity specifications on a Verimask VT 690 in both die- to-die and die-to-database modes.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David S. Alles, Paul Terbeek, Shauh-Teh Juang, James N. Wiley, and Kangmin Hsia "Reticle inspection system using DUV wavelength and new alogorithm platform for advanced reticle inspection for 0.13-μm technology node", Proc. SPIE 4066, Photomask and Next-Generation Lithography Mask Technology VII, (19 July 2000); https://doi.org/10.1117/12.392087
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reticles

Inspection

Photomasks

Deep ultraviolet

Optical proximity correction

Computing systems

Databases

RELATED CONTENT

Die to die and die to database capability analysis for...
Proceedings of SPIE (December 30 1999)
New approach to optical proximity correction
Proceedings of SPIE (December 18 1998)
SEMATECH J111 project: OPC validation
Proceedings of SPIE (June 29 1998)
EUV mask blank defect avoidance solutions assessment
Proceedings of SPIE (November 08 2012)

Back to Top