Paper
3 May 2001 Improved iodine-stabilized Nd:YAG laser
Lennart R. Robertsson, Long-Sheng Ma, Susanne Picard
Author Affiliations +
Abstract
In 1977 the 532 nm radiation obtained by frequency-double iodine-stabilized Nd:YAG lasers was included in the revised list of recommended radiations for the practical realization of the definition of the meter. In a planned group of reference lasers at this wavelength at the BIPM, the first two have been completed and a series of beat measurements has been made. The relative short-term stability was typically 5 (DOT) 10-14. Over longer durations a typical minimum stability floor of about 6 (DOT) 10-15 is reached. The frequency difference between the BIPM lasers measured over a 10-day period was found to be 63 Hz with a standard uncertainty of 161 Hz. The hyperfine spectrum of the R(56)32-0 line in iodine has been measured using beat frequency techniques and excellent agreement with theory is found, with a residual of the fit of only 400 Hz.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lennart R. Robertsson, Long-Sheng Ma, and Susanne Picard "Improved iodine-stabilized Nd:YAG laser", Proc. SPIE 4269, Laser Frequency Stabilization, Standards, Measurement, and Applications, (3 May 2001); https://doi.org/10.1117/12.424482