Paper
9 September 2002 Testing micro-optical bonds per Telcordia qualifications
Patrick A. Bournes, Vijay F. Thadani
Author Affiliations +
Abstract
A method has been developed for testing the stability of micro-optical bonds. A white light interferometer is used to measure the movement of micro-optical components after each of a series of Telcordia tests. The micro-optical components were subjected to accelerated high temperature soak, thermal cycling, thermal shock and 500 G mechanical shock. This method allows us to have a high level of confidence that our optical bonds will be sufficiently stable throughout the service life of our tunable laser product. Using accelerated testing techniques and not performing environmental tests that have been shown to induce minimal or no movement, we have found that 30 days is the time required to adequately evaluate the stability of a micro-optical bond design.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Patrick A. Bournes and Vijay F. Thadani "Testing micro-optical bonds per Telcordia qualifications", Proc. SPIE 4771, Optomechanical Design and Engineering 2002, (9 September 2002); https://doi.org/10.1117/12.482177
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Adhesives

Interferometers

Micro optics

Optical components

Epoxies

Surface finishing

Ultraviolet radiation

Back to Top