Paper
15 October 1984 Transient Attenuation In Connectors To PCS Fibers And In Glass-On-Glass Fibers Induced By Pulsed X-Rays
Joseph Zucker, Ray Clarke, Ralph Narciso
Author Affiliations +
Abstract
Using Sandia Laboratories' Hermes Ii X-Ray Pulser, We Have Measured The Transient Attenuation Of Connectors To Pcs Fiber Prepared With Raychem Fibersleeves® And Of Glass-On-Glass Silica Core Fiber (Raychem Type Vsc) Induced By 50 Nanosecond X-Ray Pulses With Total Dose Of 5 Krads. No Significant Losses Were Induced In The Connectors Either At 23°C Or At -55°C, Thus Qualifying Them For Use In A High Radiation Environment. The Peak Transient Attenuation Measured For The Fiber With 200 Micrometer Core Diameter At -55°C (7.2 Db/Km/Krad) Is Significantly Lower Than For Any Other Commercially Available Fiber At That Temperature.
© (1984) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joseph Zucker, Ray Clarke, and Ralph Narciso "Transient Attenuation In Connectors To PCS Fibers And In Glass-On-Glass Fibers Induced By Pulsed X-Rays", Proc. SPIE 0506, Fiber Optics in Adverse Environments II, (15 October 1984); https://doi.org/10.1117/12.944920
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Connectors

Signal attenuation

Optical fibers

X-rays

Temperature metrology

Cladding

Fiber optics

Back to Top