18 April 2003 Test of a processing algorithm for NIR-laser-diode-based pulse oximetry
Sonnia Maria Lopez Silva, Juan Pedro Silveira, Maria Luisa Dotor
Author Affiliations +
Proceedings Volume 5119, Bioengineered and Bioinspired Systems; (2003) https://doi.org/10.1117/12.499067
Event: Microtechnologies for the New Millennium 2003, 2003, Maspalomas, Gran Canaria, Canary Islands, Spain
Abstract
Pulse oximeters are used for the non-invasive monitoring of arterial blood hemoglobin oxygen saturation. This technique is based on the time variable optical attenuation by a vascular bed due to the cardiac pumping action (photoplethysmography) and the differential optical absorption of the oxy- and deoxy-hemoglobin. The photoplethysmographic (PPG) signals measured at two specific wavelengths are decomposed into its variable or pulsating component (EAC) and the constant or non-pulsating component (EDC) for deriving a parameter related to the arterial blood oxygen saturation (So2). Previously it has been reported a signal processing algorithm for a near infrared (NIR) laser diodes based transmittance pulse oximetry system. The main difficulties in the extraction of the information from the PPG signals are the small value of the signals variation related to their constant values, and the presence of artefacts caused by macro- and micro- movements of the part under analysis. The proposed algorithm permits the numeric separation of the variable and constant parts of the signals for both wavelengths. The EDC is obtained by a low pass filtering, and EAC by a pass-band one, followed by a non-linear filtering based on histogram reduction. In the present work is exposed the analysis of the influence of processing parameters like filters cut-off frequencies and histogram reduction percentage, on the derived So2 values. The test has been conducted both on real and simulated PPG signals. The real PPG has been recorded through experimental studies with human subjects using the NIR laser diodes based transmittance pulse oximetry system. The sources of artefacts and noise in the laser diodes PPG signals are discussed.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sonnia Maria Lopez Silva, Juan Pedro Silveira, and Maria Luisa Dotor "Test of a processing algorithm for NIR-laser-diode-based pulse oximetry", Proc. SPIE 5119, Bioengineered and Bioinspired Systems, (18 April 2003); https://doi.org/10.1117/12.499067
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Oximetry

Nonlinear filtering

Filtering (signal processing)

Near infrared

Semiconductor lasers

Linear filtering

Photoplethysmography

Back to Top