Paper
17 March 2006 Comparison of sensitivity and reading time for the use of computer aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader
F. Beyer, L. Zierott, E. M. Fallenberg, K. Juergens, J. Stoeckel, W. Heindel, D. Wormanns
Author Affiliations +
Abstract
Purpose: To compare sensitivity and reading time when using CAD as second reader resp. concurrent reader. Materials and Methods: Fifty chest MDCT scans due to clinical indication were analysed independently by four radiologists two times: First with CAD as concurrent reader (display of CAD results simultaneously to the primary reading by the radiologist); then after a median of 14 weeks with CAD as second reader (CAD results were shown after completion of a reading session without CAD). A prototype version of Siemens LungCAD (Siemens,Malvern,USA) was used. Sensitivities and reading times for detecting nodules ≥4mm of concurrent reading, reading without CAD and second reading were recorded. In a consensus conference false positive findings were eliminated. Student's T-Test was used to compare sensitivities and reading times. Results: 108 true positive nodules were found. Mean sensitivity was .68 for reading without CAD, .68 for concurrent reading and .75 for second reading. Differences of sensitivities were significant between concurrent and second reading (p<.001) resp. reading without CAD and second reading (p=.001). Mean reading time for concurrent reading was significant shorter (274s) compared to reading without CAD (294s;p=.04) and second reading (337s;p<.001). New work to be presented: To our knowledge this is the first study that compares sensitivities and reading times between use of CAD as concurrent resp. second reader. Conclusion: CAD can either be used to speed up reading of chest CT cases for pulmonary nodules without loss of sensitivity as concurrent reader -OR (and not AND) to increase sensitivity and reading time as second reader.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
F. Beyer, L. Zierott, E. M. Fallenberg, K. Juergens, J. Stoeckel, W. Heindel, and D. Wormanns "Comparison of sensitivity and reading time for the use of computer aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader", Proc. SPIE 6146, Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment, 614617 (17 March 2006); https://doi.org/10.1117/12.652051
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer aided diagnosis and therapy

Computer aided design

CAD systems

Computed tomography

Chest

Lung

Prototyping

Back to Top