Abstract
We present a system which allows for use of magnetic resonance (MR) images as primary RT workflow modality alone and no longer limits the user to computed tomography data for radiation therapy (RT) planning, simulation and patient localization. The single steps for achieving this goal are explained in detail. For planning two MR data sets, MR1 and MR2 are acquired sequentially. For MR1 a standardized Ultrashort TE (UTE) sequence is used enhancing bony anatomy. The sequence for MR2 is chosen to get optimal contrast for the target and the organs at risk for each individual patient. Both images are naturally in registration, neglecting elastic soft tissue deformations. The planning software first automatically extracts skin and bony anatomy from MR1. The user can semi-automatically delineate target structures and organs at risk based on MR1 or MR2, associate all segmentations with MR1 and create a plan in the coordinate system of MR1. Projections similar to digitally reconstructed radiographs (DRR) enhancing bony anatomy are calculated from the MR1 directly and can be used for iso-center definition and setup verification. Furthermore we present a method for creating a Pseudo-CT data set which assigns electron densities to the voxels of MR1 based on the skin and bone segmentations. The Pseudo-CT is then used for dose calculation. Results from first tests under clinical conditions show the feasibility of the completely MR based workflow in RT for necessary clinical cases. It needs to be investigated in how far geometrical distortions influence accuracy of MR-based RT planning.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thomas Boettger, Tufve Nyholm, Magnus Karlsson, Chandrasekhar Nunna, and Juan Carlos Celi "Radiation therapy planning and simulation with magnetic resonance images", Proc. SPIE 6918, Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling, 69181C (17 March 2008); https://doi.org/10.1117/12.770016
Lens.org Logo
CITATIONS
Cited by 16 scholarly publications and 5 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image segmentation

Skin

Magnetic resonance imaging

Bone

Tissues

Computed tomography

Radiotherapy

Back to Top