Paper
5 June 2008 10 kHz 54 W Ti:sapphire regenerative amplifier as a pumping laser of a laser-plasma x-ray source
Author Affiliations +
Proceedings Volume 7022, Advanced Laser Technologies 2007; 70220M (2008) https://doi.org/10.1117/12.803939
Event: Advanced Laser Technologies 2007, 2007, Levi, Finland
Abstract
We are developing a multi-kHz repetition rate high-average power Ti:sapphire regenerative amplifier as a pumping laser of a laser-plasma X-ray source. With an optimally designed ring resonator with a cryogenically-cooled laser rod, the average output power of 54 W before compression was achieved when pumped by a 180-W green laser at 10 kHz repetition rate. The focusability of the output beam was better than two times of the diffraction limit and can be compressed to 82 fs. Possibility of scaling to higher output power is discussed.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Isao Matsushima, Hidehiko Yashiro, and Toshihisa Tomie "10 kHz 54 W Ti:sapphire regenerative amplifier as a pumping laser of a laser-plasma x-ray source", Proc. SPIE 7022, Advanced Laser Technologies 2007, 70220M (5 June 2008); https://doi.org/10.1117/12.803939
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resonators

Thermal effects

Amplifiers

Optical pumping

Rod lasers

Cryogenics

Pulsed laser operation