28 August 2009 A sensitive solid-phase time-resolved fluorescence immunoassay apparatus
Yun-lei Wang, Ke-fei Song, Wei-lai Zhang, Jun-ling Li
Author Affiliations +
Proceedings Volume 7382, International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging; 73821V (2009) https://doi.org/10.1117/12.835224
Event: International Symposium on Photoelectronic Detection and Imaging 2009, 2009, Beijing, China
Abstract
In the device, a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source, and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA)[1]. The first one is to design optimum exciting optical system, so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least, the sample fluorescence through the integrating sphere and come to the grating monochromator, The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device, SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process, signal-to-noise ratio(SNR) will be improved, also adjust delay time, ampling frequency and sampling number arbitrarily. By testing, the sensitivity is 10-12mol/L(substance marked by Eu3+), examination repeat is ≤2.5%, examination linearity is from 10-8mol/L to 10-12mol/L, correlation coefficient is 99.98%(p≤0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody , and solve the tumor, genetic variation, the virus protein detection.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yun-lei Wang, Ke-fei Song, Wei-lai Zhang, and Jun-ling Li "A sensitive solid-phase time-resolved fluorescence immunoassay apparatus", Proc. SPIE 7382, International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, 73821V (28 August 2009); https://doi.org/10.1117/12.835224
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Time resolved spectroscopy

Monochromators

Signal processing

Data centers

Data conversion

Holography

Back to Top