Paper
28 February 2014 The Uppsala Contrast Sensitivity Test (UCST): A fast strategy for clinical assessment of contrast sensitivity
Lars D. Malmqvist, Per G. Söderberg
Author Affiliations +
Proceedings Volume 8930, Ophthalmic Technologies XXIV; 89300H (2014) https://doi.org/10.1117/12.2054403
Event: SPIE BiOS, 2014, San Francisco, California, United States
Abstract
Routine clinical measurement of spectral contrast sensitivity is hampered by the time consumption of current methods. We are developing a system that allows instantaneous measurement of spectral contrast sensitivity. The UCST system consists of custom software running on an iPad connected to a calibrated TFT-monitor. Twenty healthy subjects were consecutively randomized to have their spectral contrast sensitivity measured with the UCST strategy or with a Vistech VCTS 6500 chart. The examination time and the spectral contrast sensitivity, respectively, were recorded for each eye in each subject. The Vistech strategy resulted in a more extended mean examination time (CI-Vistech:± (0.95) = 87 ±27 s, d.f. = 9) than the UCST strategy (CI-UCST:μ (0.95) = 13 ±4 s, d.f. = 9), and the estimated mean difference between the two strategies indicated a difference in examination time (CI-difference:μ (0.95) = [47;106] s, d.f. = 18). The overall contrast sensitivity for each group was estimated as the contrast sensitivities for the spatial frequencies sampled, integrated over the spatial frequency band sampled. The Vistech strategy resulted in a higher estimated mean overall contrast sensitivity (CI-Vistech:μ (0.95) = 116±24 log rel.·log [c.·deg-1], d.f. = 9) than the UCST strategy (CIUCST: μ (0.95) = 74±14 log rel.·log [c.·deg-1], d.f. = 9), and the estimated mean difference between the two strategies indicated a difference in overall contrast sensitivity (CI-difference:μ (0.95) = [15;68] log rel.·log [c.·deg-1]), d.f. = 18). It is concluded that the UCST strategy measures spectral contrast sensitivity on the order of 7 times faster than the Vistech strategy. The slightly lower overall contrast sensitivity recorded for the UCST strategy appeared to be due to a limitation in dynamic range that can be overcome with improved design.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lars D. Malmqvist and Per G. Söderberg "The Uppsala Contrast Sensitivity Test (UCST): A fast strategy for clinical assessment of contrast sensitivity", Proc. SPIE 8930, Ophthalmic Technologies XXIV, 89300H (28 February 2014); https://doi.org/10.1117/12.2054403
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Contrast sensitivity

Spatial frequencies

Calibration

Eye

Visualization

Manufacturing

Statistical analysis

RELATED CONTENT

Adaptation to blur
Proceedings of SPIE (June 08 2001)
Visual sensitivity to color-varying stimuli
Proceedings of SPIE (August 27 1992)
Impact of adaptation time on contrast sensitivity
Proceedings of SPIE (February 23 2010)

Back to Top