18 March 2015 Theoretical and experimental comparison of image signal and noise for dual-energy subtraction angiography and conventional x-ray angiography
Author Affiliations +
Abstract
Cardiovascular disease is currently the leading cause of mortality worldwide. Digital subtraction angiography (DSA) is widely used to enhance the visibility of small vessels and vasculature obscurred by overlying bone and lung fields by subtracting a mask and contrast image. However, motion between these mask and contrast images can introduce artifacts that can render a study non-diagnostic. This makes DSA particularly unsuccessful for cardiac imaging. A method called dual-energy, or energy subtraction angiography (ESA), was proposed in the past as an alternative for vascular imaging, however it was not pursued because experimental results suggested that image quality was deemed as poor and inferior to DSA. Image quality for angiography comes down to iodine signal and noise. In this paper we investigate the fundamental iodine signal and noise analysis of ESA and compare it to DSA. Method: We developed a polyenergetic and monoenergetic theoretical model for iodine signal and noise for both ESA and DSA. We validated our polyenergetic model by experiment where ESA and DSA images of a vascular phantom were acquired using an x-ray system with a flat panel CsI Xmaru1215CF-MPTM (Rayence Co., Ltd., Republic of Korea) detector. For ESA low and high applied tube voltages of 50 kV and 120 kV (2.5 mmCu), respectively, and for DSA the applied tube voltage was 80 kV. Iodine signal-to-noise ratio (SNR) per entrance exposure was calculated for each iodine concentration for both ESA and DSA. Results: Our measured iodine SNR agreed well with theoretical calculations. Iodine SNR for ESA was relatively higher than DSA for low iodine mass loadings, and as iodine mass loading increases iodine SNR decreases. Conclusions: We have developed a model for iodine SNR for both DSA and ESA. Our model was validated with experiment and showed excellent agreement. We have shown that there is potential for obtaining iodine-specific images using ESA that are similar to DSA.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christiane S. Burton, John R. Mayo, and I. A. Cunningham "Theoretical and experimental comparison of image signal and noise for dual-energy subtraction angiography and conventional x-ray angiography", Proc. SPIE 9412, Medical Imaging 2015: Physics of Medical Imaging, 941219 (18 March 2015); https://doi.org/10.1117/12.2082724
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Iodine

Signal to noise ratio

Sensors

Angiography

X-rays

Interference (communication)

Quantum wells

Back to Top