8 June 2016 Calibrating IR cameras for in-situ temperature measurement during the electron beam melt processing of Inconel 718 and Ti-Al6-V4
R. B. Dinwiddie, M. M. Kirka, P. D. Lloyd, R. R. Dehoff, L. E. Lowe, G. S. Marlow
Author Affiliations +
Abstract
High performance mid-wave infrared (IR) cameras are used for in-situ electron beam melt process monitoring and temperature measurements. Since standard factory calibrations are insufficient due to very low transmissions of the leaded glass window required for X-ray absorption, two techniques for temperature calibrations are compared. In-situ measurement of emittance will also be discussed. Ultimately, these imaging systems have the potential for routine use for online quality assurance and feedback control.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. B. Dinwiddie, M. M. Kirka, P. D. Lloyd, R. R. Dehoff, L. E. Lowe, and G. S. Marlow "Calibrating IR cameras for in-situ temperature measurement during the electron beam melt processing of Inconel 718 and Ti-Al6-V4", Proc. SPIE 9861, Thermosense: Thermal Infrared Applications XXXVIII, 986107 (8 June 2016); https://doi.org/10.1117/12.2229070