Paper
5 March 1993 Fiber optic gyroscope using proton exchange lithium tantalate integrated optics chip
Kevin Mark Killian, Andrew John Maltenfort
Author Affiliations +
Proceedings Volume 1795, Fiber Optic and Laser Sensors X; (1993) https://doi.org/10.1117/12.141233
Event: Fibers '92, 1992, Boston, MA, United States
Abstract
We compare the use of lithium tantalate and lithium niobate as a substrate material for integrated optics chips for fiber optic gyroscopes. We also show the performance of a fiber optic gyroscope using a proton exchange lithium tantalate chip. The results indicate that, when normalized for detected power, the gyroscope built with the lithium tantalate chip performs as well as that with the lithium niobate chip.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kevin Mark Killian and Andrew John Maltenfort "Fiber optic gyroscope using proton exchange lithium tantalate integrated optics chip", Proc. SPIE 1795, Fiber Optic and Laser Sensors X, (5 March 1993); https://doi.org/10.1117/12.141233
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lithium

Fiber optic gyroscopes

Gyroscopes

Lithium niobate

Integrated optics

Modulators

Waveguides

RELATED CONTENT

Integrated optics for fiber optic sensors
Proceedings of SPIE (February 01 1991)
Low-drift fiber-optic gyro for earth-rate applications
Proceedings of SPIE (August 01 1991)
Fiber Gyro With Electro-Optic Phase Modulation
Proceedings of SPIE (March 11 1987)
Integrated optical device in a fiber gyroscope
Proceedings of SPIE (August 01 1991)
Source module with IOC and detectors for low cost fiber...
Proceedings of SPIE (November 12 1996)

Back to Top