Paper
24 October 1984 Measurements Of Coronary Mean Transit Time And Myocardial Tissue Blood Flow By Deconvolution Of Intravasal Tracer Dilution Curves
H. Korb, A. Hoeft, G. Hellige
Author Affiliations +
Abstract
Previous studies have shown that intramyocardial blood volume does not vary to a major extent even during extreme variation of hemodynamics and coronary vascular tone. Based on a constant intramyocardial blood volume it is therefore possible to calculate tissue blood flow from the mean transit time of an intravascular tracer. The purpose of this study was to develop a clinically applicable method for measurement of coronary blood flow. The new method was based on indocyanine green, a dye which is bound to albumin and intravasally detectable by means of a fiberoptic catheter device. One fiberoptic catheter was placed in the aortic root and another in the coronary sinus. After central venous dye injection the resulting arterial and coronary venous dye dilution curves were processed on-line by a micro-computer. The mean transit time as well as myocardial blood flow were calculated from the step response function of the deconvoluted arterial and coronary venous signals. Reference flow was determined with an extracorporeal electromagnetic flowprobe within a coronary sinus bypass system. 38 steady states with coronary blood flow ranging from 49 - 333 ml/min*100g were analysed in 5 dogs. Mean transit times varied from 2.9 to 16.6 sec. An average intracoronary blood volume of 13.9 -7 1.8 m1/100g was calculated. The correlation between flow determined by the dye dilution technique and flow measured with the reference method was 0.98. According to these results determination of coronary blood flow with a double fiberoptic system and indocyanine green should be possible even under clinical conditions. Furthermore, the arterial and coronary venous oxygen saturation can be monitored continuously by the fiberoptic catheters. Therefore, additional information about the performance of the heart such as myocardial oxygen consumption and myocardial efficiency is available with the same equipment.
© (1984) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
H. Korb, A. Hoeft, and G. Hellige "Measurements Of Coronary Mean Transit Time And Myocardial Tissue Blood Flow By Deconvolution Of Intravasal Tracer Dilution Curves", Proc. SPIE 0494, Novel Optical Fiber Techniques for Medical Applications, (24 October 1984); https://doi.org/10.1117/12.943905
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood circulation

Blood

Fiber optics

Oxygen

Tissues

Indocyanine green

Deconvolution

Back to Top