0

Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Accurate calibration of a fringe projection system by considering telecentricity

[+] Author Affiliations
Klaus Haskamp, Markus Kästner, Eduard Reithmeier

Leibniz Univ. Hannover (Germany)

Proc. SPIE 8082, Optical Measurement Systems for Industrial Inspection VII, 80821B (May 26, 2011); doi:10.1117/12.888037
Text Size: A A A
From Conference Volume 8082

  • Optical Measurement Systems for Industrial Inspection VII
  • Peter H. Lehmann; Wolfgang Osten; Kay Gastinger
  • Munich, Germany | May 23, 2011

abstract

Fringe projection systems can be used for the measurement of complex workpiece geometries. Virtual fringe projection systems can be used for the calculation of optimal measurement strategies with respect to criteria like a minimal measurement uncertainty. This is the main field of research of the subproject B5 of the collaborative research centre 489 (CRC 489), funded by the German Research Foundation (DFG). The main task of the subproject is to develop a virtual multisensor assistance system for the calculation of workpiece adapted measurement strategies. This paper focuses on the model and calibration of the used fringe projection sensor. The sensor has to be modelled and the system parameters have to be identified by an accurate calibration procedure. The used fringe projection system has a camera lens with an object-sided telecentricity. Usually, the components projector and camera were described using a pinhole model, which does not reflect the telecentricity. This means, that the existing physical formulations and calibration procedures cannot be used, here. In this paper, the model and calibration strategy for the calculation of the system parameters are described in detail. In order to get a precise simulation model, each intrinsic and extrinsic parameter is considered. To verify the virtual model and the calibration strategy, the calibration was repeated and the standard deviation of the parameters was calculated. Furthermore an optical flat and a groove artefact will be measured and the planarity of the optical flat and the depth of the groove artefact will be determined and compared to the calibrated values.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Klaus Haskamp ; Markus Kästner and Eduard Reithmeier
"Accurate calibration of a fringe projection system by considering telecentricity", Proc. SPIE 8082, Optical Measurement Systems for Industrial Inspection VII, 80821B (May 26, 2011); doi:10.1117/12.888037; http://dx.doi.org/10.1117/12.888037


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
 

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


Buy this article ($18 for members, $25 for non-members).
Sign In