Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Quantification of the migration and deformation of abdominal aortic aneurysm stent grafts

[+] Author Affiliations
Julian Mattes, Michael Netzer, Karl Fritscher, Rainer Schubert

Univ. for Health Sciences, Medical Informatics and Technology (Austria)

Iris Steingruber, Helmut Kopf, Werner Jaschke

Innsbruck Medical Univ. (Austria)

Proc. SPIE 6144, Medical Imaging 2006: Image Processing, 61440V (March 10, 2006); doi:10.1117/12.653990
Text Size: A A A
From Conference Volume 6144

  • Medical Imaging 2006: Image Processing
  • Joseph M. Reinhardt; Josien P. W. Pluim
  • San Diego, CA | February 11, 2006

abstract

The endovascular repair of an abdominal aortic aneurysm is a minimal invasive therapy which has been established during the past 15 years. A stent-graft is placed inside the aorta in order to cover the weakened regions of its wall. During a time interval of one or more years the stent-graft can migrate and deform with the risk of the occlusion of one of its limbs or of the rupture of the aneurysm. In this work we developed several strategies to quantify the migration and deformation in order to assess the risk coming with these movements and especially to characterize appearing complications by them. We calculated the rigid movement of the stent-graft and the aorta relative to the spinal canal. For this purpose, firstly, we rigidly registered the spinal canals, extracted for the different points in time, in order to establish a fixed reference system. All objects have been segmented first and surface points have been determined before applying a rigid and non-rigid point set registration algorithm. The change in the residual error after registration of the stent-graft with an increasing number of degrees of freedom indicates the amount of change in the stent-graft's morphology. We investigated a sample of 9. Two cases could be clearly distinguished by the quantified parameters: a high global migration and a strong reduction of the residual error after non-rigid registration. In both cases, strong complications have been detected by the examination of clinical experts but only by means of the images acquired one year later.

© (2006) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.

Topics

Abdomen
Citation

Julian Mattes ; Iris Steingruber ; Michael Netzer ; Karl Fritscher ; Helmut Kopf, et al.
"Quantification of the migration and deformation of abdominal aortic aneurysm stent grafts", Proc. SPIE 6144, Medical Imaging 2006: Image Processing, 61440V (March 10, 2006); doi:10.1117/12.653990; http://dx.doi.org/10.1117/12.653990


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.