Signaling local non-credibility in an automatic segmentation pipeline

[+] Author Affiliations
Joshua H. Levy, Robert E. Broadhurst, Edward L. Chaney, Stephen M. Pizer

Univ. of North Carolina, Chapel Hill

Surajit Ray

Boston Univ.

Proc. SPIE 6512, Medical Imaging 2007: Image Processing, 65123Q (March 07, 2007); doi:10.1117/12.709015
Text Size: A A A
From Conference Volume 6512

  • Medical Imaging 2007: Image Processing
  • Josien P. W. Pluim; Joseph M. Reinhardt
  • San Diego, CA | February 17, 2007

abstract

The advancing technology for automatic segmentation of medical images should be accompanied by techniques to inform the user of the local credibility of results. To the extent that this technology produces clinically acceptable segmentations for a significant fraction of cases, there is a risk that the clinician will assume every result is acceptable. In the less frequent case where segmentation fails, we are concerned that unless the user is alerted by the computer, she would still put the result to clinical use. By alerting the user to the location of a likely segmentation failure, we allow her to apply limited validation and editing resources where they are most needed. We propose an automated method to signal suspected non-credible regions of the segmentation, triggered by statistical outliers of the local image match function. We apply this test to m-rep segmentations of the bladder and prostate in CT images using a local image match computed by PCA on regional intensity quantile functions. We validate these results by correlating the non-credible regions with regions that have surface distance greater than 5.5mm to a reference segmentation for the bladder. A 6mm surface distance was used to validate the prostate results. Varying the outlier threshold level produced a receiver operating characteristic with area under the curve of 0.89 for the bladder and 0.92 for the prostate. Based on this preliminary result, our method has been able to predict local segmentation failures and shows potential for validation in an automatic segmentation pipeline.

© (2007) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Joshua H. Levy ; Robert E. Broadhurst ; Surajit Ray ; Edward L. Chaney and Stephen M. Pizer
"Signaling local non-credibility in an automatic segmentation pipeline", Proc. SPIE 6512, Medical Imaging 2007: Image Processing, 65123Q (March 07, 2007); doi:10.1117/12.709015; http://dx.doi.org/10.1117/12.709015


Access This Article
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
 
Sign In to Access Full Content

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
Buy this article ($18 for members, $25 for non-members).
Sign In