Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: observer performance study

[+] Author Affiliations
Berkman Sahiner, Lubomir M. Hadjiiski, Heang-Ping Chan, Jiazheng Shi, Philip N. Cascade, Ella A. Kazerooni, Chuan Zhou, Jun Wei, Aamer R. Chughtai, Chad Poopat, Thomas Song, Jadranka S. Nojkova, Luba Frank, Anil Attili

Univ. of Michigan

Proc. SPIE 6515, Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment, 65151D (March 20, 2007); doi:10.1117/12.709851
Text Size: A A A
From Conference Volume 6515

  • Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment
  • Yulei Jiang; Berkman Sahiner
  • San Diego, CA | February 17, 2007

abstract

The purpose of this study was to evaluate the effect of computer-aided diagnosis (CAD) on radiologists' performance for the detection of lung nodules on thoracic CT scans. Our computer system was designed using an independent training set of 94 CT scans in our laboratory. The data set for the observer performance study consisted of 48 CT scans. Twenty scans were collected from patient files at the University of Michigan, and 28 scans by the Lung Imaging Database Consortium (LIDC). All scans were read by multiple experienced thoracic radiologists to determine the true nodule locations, defined as any region identified by one or more expert radiologists as containing a nodule larger than 3 mm in diameter. Eighteen CT examinations were nodule-free, while the remaining 30 CT examinations contained a total of 73 nodules having a median size of 5.5 mm (range 3.0-36.4 mm). Four other study radiologists read the CT scans first without and then with CAD, and provided likelihood of nodule ratings for suspicious regions. Two of the study radiologists were fellowship trained in cardiothoracic radiology, and two were cardiothoracic radiology fellows. Freeresponse receiver-operating characteristic (FROC) curves were used to compare the two reading conditions. The computer system had a sensitivity of 79% (58/73) with an average of 4.9 marks per normal scan (88/18). Jackknife alternative FROC (JAFROC) analysis indicated that the improvement with CAD was statistically significant (p=0.03).

© (2007) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Berkman Sahiner ; Lubomir M. Hadjiiski ; Heang-Ping Chan ; Jiazheng Shi ; Philip N. Cascade, et al.
"Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: observer performance study", Proc. SPIE 6515, Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment, 65151D (March 20, 2007); doi:10.1117/12.709851; http://dx.doi.org/10.1117/12.709851


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.