abstract

We have measured the intensity profile and transmission of x-rays focused by a series of bi-concave parabolic unit lenses fabricated in lithium and beryllium. For specified focal length and photon energy, lithium and beryllium compound refractive lenses (CRL) have a larger transmission, aperture size, and gain compared to aluminum, epoxy, and kapton CRLs. One Li CRL was composed of 335 bi-concave, parabolic unit lenses, each with an on-axis radius of curvature of 0.95 mm. This Li CRL achieved a 95 cm focal length at 8 keV with an effective aperture of 1 mm, an on-axis (peak) transmission of 26 %, and an on-axis intensity gain of 18.9. The beryllium compound refractive lens was composed of 160 bi-concave unit lenses, each with a radius of curvature of 1.9 mm. The Be CRL achieved two-dimensional focusing at 6.5 keV with a gain of 1.5, peak transmission of 9 %, focal length of 93 cm, and an effective aperture of 600 μm. Based upon the principle of spontaneous emission amplification in an FEL wiggler, coherent x-ray sources are being developed with wavelengths of 1-1.5 Å and source diameters of 50-80 μm, and the Be and Li CRL may be used to provide a small, intense image. For these coherent x-ray source parameters, the large apertures of Be and Li CRLs enable intensity gains of 105 to 106.

© (2004) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

J. T. Cremer ; Melvin A. Piestrup ; Charles K. Gary and Richard H. Pantell
"Large-aperture compound refractive lenses", Proc. SPIE 5194, Fourth-Generation X-Ray Sources and Ultrafast X-Ray Detectors, 62 (January 28, 2004); doi:10.1117/12.514857; http://dx.doi.org/10.1117/12.514857


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.