Paper
12 July 2007 Algorithms for muscle oxygenation monitoring corrected for adipose tissue thickness
Dmitri Geraskin, Petra Platen, Julia Franke, Matthias Kohl-Bareis
Author Affiliations +
Abstract
The measurement of skeletal muscle oxygenation by NIRS methods is obstructed by the subcutaneous adipose tissue which might vary between < 1 mm to more than 12 mm in thickness. A new algorithm is developed to minimize the large scattering effect of this lipid layer on the calculation of muscle haemoglobin / myoglobin concentrations. First, we demonstrate by comparison with ultrasound imaging that the optical lipid signal peaking at 930 nm is a good predictor of the adipose tissue thickness (ATT). Second, the algorithm is based on measurements of the wavelength dependence of the slope &Dgr;A/&Dgr;&rgr; of attenuation A with respect to source detector distance &rgr; and Monte Carlo simulations which estimate the muscle absorption coefficient based on this slope and the additional information of the ATT. Third, we illustrate the influence of the wavelength dependent transport scattering coefficient of the new algorithm by using the solution of the diffusion equation for a two-layered turbid medium. This method is tested on experimental data measured on the vastus lateralis muscle of volunteers during an incremental cycling exercise under normal and hypoxic conditions (corresponding to 0, 2000 and 4000 m altitude). The experimental setup uses broad band detection between 700 and 1000 nm at six source-detector distances. We demonstrate that the description of the experimental data as judged by the residual spectrum is significantly improved and the calculated changes in oxygen saturation are markedly different when the ATT correction is included.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dmitri Geraskin, Petra Platen, Julia Franke, and Matthias Kohl-Bareis "Algorithms for muscle oxygenation monitoring corrected for adipose tissue thickness", Proc. SPIE 6629, Diffuse Optical Imaging of Tissue, 66290P (12 July 2007); https://doi.org/10.1117/12.727854
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Tissue optics

Monte Carlo methods

Near infrared spectroscopy

Signal attenuation

Ultrasonography

Absorption

Back to Top