Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Advantages of monochromatic x-rays for imaging

[+] Author Affiliations
M. Hoheisel

Siemens AG Medical Solutions (Germany)

R. Lawaczeck, H. Pietsch

Schering AG Diagnostics and Radiopharmaceuticals Research (Germany)

V. Arkadiev

Institut fur Angewandte Photonik e.V. (Germany) and Institute for Scientific Instruments GmbH (Germany)

Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, 1087 (August 30, 2005); doi:10.1117/12.593398
Text Size: A A A
From Conference Volume 5745

  • Medical Imaging 2005: Physics of Medical Imaging
  • Michael J. Flynn
  • San Diego, CA | February 12, 2005

abstract

The contrast of X-ray imaging depends on the radiation energy and acquires its maximum value at a certain optimum energy typical for the object under investigation. Usually, higher energies result in reduced contrast, lower energies are absorbed in the object thus having a smaller probability of reaching the detector. Therefore, broad X-ray spectra contain non-optimal quanta to a large extent and deliver images with deteriorated contrast. Since investigations with monochromatic X-rays using synchrotrons are too complex and expensive for routine diagnostic imaging procedures, we propose a simpler approach. A conventional mammography system (Siemens Mammomat 300) with an X-ray tube with a molybdenum anode was supplemented with an X-ray HOPG monochromator (HOPG = Highly Oriented Pyrolytic Graphite) and an exit slit selecting those rays fulfilling Bragg"s condition. The detector is a CCD (Thales TH9570), 4092 x 200 pixels, 54 μm in size. At this slot-scan setup1, measurements have been carried out at 17.5 keV as well as with a polychromatic spectrum with 35 kV tube voltage. The modulation transfer function (MTF) and the detective quantum efficiency (DQE) have been determined from images of a lead bar pattern and flat-field images. Both MTF and DQE depend on orientation (scan or detector direction) for the 17.5 keV monochromatic case. Above 3 mm-1 the DQE values are smaller than those for polychromatic radiation. The contrast yielded by foils of different materials (Al, Cu, Y, Ag) has been studied. In all cases the monochromatic X-rays give rise to about twice the contrast of a polychromatic spectrum.

© (2005) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

M. Hoheisel ; R. Lawaczeck ; H. Pietsch and V. Arkadiev
"Advantages of monochromatic x-rays for imaging", Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, 1087 (August 30, 2005); doi:10.1117/12.593398; http://dx.doi.org/10.1117/12.593398


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.