Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

High-sensitivity uncooled microcantilever infrared imaging arrays

[+] Author Affiliations
Scott R. Hunter, Gregory Maurer, Lijun Jiang, Gregory Simelgor

Multispectral Imaging, Inc.

Proc. SPIE 6206, Infrared Technology and Applications XXXII, 62061J (May 17, 2006); doi:10.1117/12.664727
Text Size: A A A
From Conference Volume 6206

  • Infrared Technology and Applications XXXII
  • Bjørn F. Andresen; Gabor F. Fulop; Paul R. Norton
  • Orlando (Kissimmee), FL | April 17, 2006

abstract

The design and operation of an advanced bimorph microcantilever based infrared imaging detector are presented. This technology has the potential to achieve very high sensitivities due to its inherent high responsivity and low noise sensor and detection electronics. The sensor array is composed of bimaterial, thermally sensitive microcantilever structures that are the moving elements of variable plate capacitors. The heat sensing microcantilever structures are integrated with CMOS control and amplification electronics to produce a low cost imager that is compatible with standard silicon IC foundry processing and materials. The bimorph sensor structure is fabricated using low thermal expansion, high thermal isolation silicon oxide and oxynitride materials, and a high thermal expansion aluminum alloy bimetal. The microcantilever paddle is designed to move away from the substrate at elevated imaging temperatures, leading to large modeled sensor dynamic ranges (~16 bits). A temperature coefficient of capacitance, ▵C/C, (equivalent to TCR for microbolometers) above 30% has been modeled and measured for these structures, leading to modeled NEDT < 20 mK and thermal time constants in the 5-10 msec range giving a figure-of-merit [1] NEDT.Tau = 100-200 mK.msec. The development efforts to date have focused on the fabrication of 160x120 pixel arrays with 50 micron pitch pixels. Results from detailed thermo-electro-opto-mechanical modeling of the operation of these sensors are compared with experimental measurements from various test and integrated sensor structures and arrays.

© (2006) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Scott R. Hunter ; Gregory Maurer ; Lijun Jiang and Gregory Simelgor
"High-sensitivity uncooled microcantilever infrared imaging arrays", Proc. SPIE 6206, Infrared Technology and Applications XXXII, 62061J (May 17, 2006); doi:10.1117/12.664727; http://dx.doi.org/10.1117/12.664727


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.