Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Frame-by-frame 3D catheter tracking methods for an inverse geometry cardiac interventional system

[+] Author Affiliations
Michael A. Speidel, Michael S. Van Lysel

Univ. of Wisconsin, Madison

Augustus P. Lowell, Joseph A. Heanue

Triple Ring Technologies, Inc.

Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 69131I (March 18, 2008); doi:10.1117/12.772745
Text Size: A A A
From Conference Volume 6913

  • Medical Imaging 2008: Physics of Medical Imaging
  • Jiang Hsieh; Ehsan Samei
  • San Diego, CA | February 16, 2008

abstract

The Scanning-Beam Digital X-ray (SBDX) system performs rapid scanning of a narrow x-ray beam using an electronically scanned focal spot and inverse beam geometry. SBDX's ability to perform real-time multi-plane tomosynthesis with high dose efficiency is well-suited to interventional procedures such as left atrial ablation, where precise knowledge of catheter positioning is desired and imaging times are long. We describe and evaluate techniques for frame-by-frame 3D localization of multiple catheter electrodes from the stacks of tomosynthetic images generated by SBDX. The localization algorithms operate on gradient-filtered versions of the tomosynthetic planes. Small high contrast objects are identified by thresholding the stack of images and applying connected component analysis. The 3D coordinate of each object is the center-of-mass of each connected component. Simulated scans of phantoms containing 1-mm platinum spheres were used to evaluate localization performance with the SBDX prototype (5.5 × 5.5 cm detector, 3° tomographic angle) and a with new SBDX detector under design (10-cm wide × 6 cm, 6° × 3°). Z-coordinate error with the SBDX prototype was -0.6 +/- 0.7 mm (mean+/-standard deviation) with 28 cm acrylic, 24.3 kWp source operation, and 12-mm plane spacing. Localization improved to -0.3 +/- 0.3 mm using the wider SBDX detector and a 3-mm plane spacing. The effects of tomographic angle, plane-to-plane spacing, and object velocity are evaluated, and a simulation demonstrating ablation catheter localization within a real anatomic background is presented. Results indicate that SBDX is capable of precise real-time 3D tracking of high contrast objects.

© (2008) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Michael A. Speidel ; Augustus P. Lowell ; Joseph A. Heanue and Michael S. Van Lysel
"Frame-by-frame 3D catheter tracking methods for an inverse geometry cardiac interventional system", Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 69131I (March 18, 2008); doi:10.1117/12.772745; http://dx.doi.org/10.1117/12.772745


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.