7 September 2006 A beam hardening correction method based on HL consistency
Author Affiliations +
Abstract
XCT with polychromatic tube spectrum causes artifact called beam hardening effect. The current correction in CT device is carried by apriori polynomial from water phantom experiment. This paper proposes a new beam hardening correction algorithm that the correction polynomial depends on the relativity of projection data in angles, which obeys Helgasson-Ludwig Consistency (HL Consistency). Firstly, a bi-polynomial is constructed to characterize the beam hardening effect based on the physical model of medical x-ray imaging. In this bi-polynomial, a factor r(γ,β) represents the ratio of the attenuation contributions caused by high density mass (bone, etc.) to low density mass (muscle, vessel, blood, soft tissue, fat, etc.) respectively in the projection angle β and fan angle γ. Secondly, let r(γ,β)=0, the bi-polynomial is degraded as a sole-polynomial. The coefficient of this polynomial can be calculated based on HL Consistency. Then, the primary correction is reached, which is also more efficient in theoretical than the correction method in current CT devices. Thirdly, based on the result of a normal CT reconstruction from the corrected projection data, r(γ,β) can be estimated. Fourthly, the coefficient of bi-polynomial can also be calculated based HL Consistency and the final correction are achieved. Experiments of circular cone beam CT indicate this method an excellent property. Correcting beam hardening effect based on HL Consistency, not only achieving a self-adaptive and more precise correction, but also getting rid of regular inconvenient water phantom experiments, will renovate the correction technique of current CT devices.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xuanqin Mou, Shaojie Tang, and Hengyong Yu "A beam hardening correction method based on HL consistency", Proc. SPIE 6318, Developments in X-Ray Tomography V, 63181U (7 September 2006); https://doi.org/10.1117/12.682869
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

X-ray sources

X-ray imaging

Head

Sensors

Tissues

Aluminum

RELATED CONTENT

3D x-ray reconstruction using lightfield imaging
Proceedings of SPIE (September 05 2014)
Single scan energy selective imaging on cone beam CT ...
Proceedings of SPIE (March 06 2013)
Laboratory soft x-ray source with foil target
Proceedings of SPIE (February 03 1993)
Comparison on beam hardening correction of CT based on H...
Proceedings of SPIE (September 07 2006)

Back to Top