Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Accuracy of the nonlinear fitting procedure for time-resolved measurements on diffusive phantoms at NIR wavelengths

[+] Author Affiliations
Lorenzo Spinelli, Andrea Farina, Antonio Pifferi, Alessandro Torricelli, Rinaldo Cubeddu

IIT, ULTRAS–INFM–CNR and IFN–CNR, Politecnico di Milano (Italy)

Fabrizio Martelli, Giovanni Zaccanti

Univ. degli Studi di Firenze (Italy)

Proc. SPIE 7174, Optical Tomography and Spectroscopy of Tissue VIII, 717424 (February 12, 2009); doi:10.1117/12.808997
Text Size: A A A
From Conference Volume 7174

  • Optical Tomography and Spectroscopy of Tissue VIII
  • Bruce J. Tromberg; Arjun G. Yodh; Mamoru Tamura; Eva M. Sevick-Muraca; Robert R. Alfano
  • San Jose, CA | January 24, 2009

abstract

In this work we studied the accuracy of a non-linear fitting procedure, based on the Levenberg-Marquardt algorithm, for time-resolved measurements to retrieve the absorption and the reduced scattering coefficients of an absorbing diffusive medium. This procedure is suitable for retrieving optical properties in a wider range of situations (e.g. solid samples, reflectance geometry), with respect to the linear inversion procedures recently presented for both CW and time domain measurements. By means of both analytical and numerical (Monte Carlo) simulations, we quantified the influence of photon counts, temporal sampling, analytical model, background and instrument response function on the accuracy in the estimation of the optical properties. Also a new analytical model to describe light propagation in diffusive media based on the Radiative Transport Equation has been considered. The main source of error that affects the accuracy of the absorption and reduced scattering coefficients retrieved by the non-linear procedure appears to be the analytical model adopted in the inversion procedure.

© (2009) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Lorenzo Spinelli ; Fabrizio Martelli ; Andrea Farina ; Antonio Pifferi ; Alessandro Torricelli, et al.
"Accuracy of the nonlinear fitting procedure for time-resolved measurements on diffusive phantoms at NIR wavelengths", Proc. SPIE 7174, Optical Tomography and Spectroscopy of Tissue VIII, 717424 (February 12, 2009); doi:10.1117/12.808997; http://dx.doi.org/10.1117/12.808997


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.