Paper
8 March 2007 Colorimetric evaluation of composite materials with different thickness by reflectance spectroscopy
Priscila Paiva Portero D.D.S., Fernando Florez D.D.S., Vanderlei Bagnato D.D.S., Osmir Batista de Oliveira Jr., Leonor de Castro Monteiro Loffredo
Author Affiliations +
Proceedings Volume 6425, Lasers in Dentistry XIII; 64250Z (2007) https://doi.org/10.1117/12.700992
Event: SPIE BiOS, 2007, San Jose, California, United States
Abstract
Selection of the proper shade and color matching of restorations to natural dentition continues to be one of the most frustrating problems in dentistry and currently available shade guide presents a limited selection of colors compared to those found in natural dentition. This investigation evaluation if the composites resins shade B2 are equivalent to the Vita shade guide B2. Twelve composite resins (Renamel Microfill Super Brite- Cosmedent USA, Renamel Universal Brite- Cosmedent USA, Renamel Microfill Body- Cosmedent USA, Renamel Universal Body- Cosmedent USA, Opallis EB2-FGM, Opallis DB2-FGM, Filtek Supreme XT-3M/ESPE, Filtek Z250-3M/ESPE, Filtek Z350-3M/ESPE, Z100-3M/ESPE, 4 Seasons Dentin-Ivoclar/Vivadent, Tetric Ceram-Ivoclar/Vivadent) shade B2 were used. From each composite, two specimens were made in a steel matrix with 8.0 mm diameter and 10.0 mm different predetermined thickness (0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0 mm). The specimens were 40 seconds light polymerized by LED Ultrablue (DMC). The specimens were measured 10 times each to determine the shade using a reflectance spectrophotometer (Pocket Spec). According to results was verified that not any of composites resins shade B2 evaluated in this study presented values of color difference (ΔE) equivalent to the Vita shade guide B2 and the 2 mm thickness showed the closer match to the Vita shade guide B2.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Priscila Paiva Portero D.D.S., Fernando Florez D.D.S., Vanderlei Bagnato D.D.S., Osmir Batista de Oliveira Jr., and Leonor de Castro Monteiro Loffredo "Colorimetric evaluation of composite materials with different thickness by reflectance spectroscopy", Proc. SPIE 6425, Lasers in Dentistry XIII, 64250Z (8 March 2007); https://doi.org/10.1117/12.700992
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Composite resins

Spectrophotometry

Dentistry

Teeth

Composites

Color difference

Visualization

Back to Top