Intensity-modulated fluence patterns for task-specific imaging in cone-beam CT

[+] Author Affiliations
S. A. Graham, J. H. Siewerdsen

Univ. of Toronto (Canada) and Ontario Cancer Institute (Canada)

D. A. Jaffray

Univ. of Toronto (Canada) and Ontario Cancer Institute (Canada) and Princess Margaret Hospital (Canada)

Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 651003 (March 13, 2007); doi:10.1117/12.713724
Text Size: A A A
From Conference Volume 6510

  • Medical Imaging 2007: Physics of Medical Imaging
  • Jiang Hsieh; Michael J. Flynn
  • San Diego, CA | February 17, 2007

abstract

Cone-beam CT images of a patient with a pre-defined distribution of noise in the image and dose to the patient can be accomplished through the development of advanced compensation schemes. Such compensation schemes involve delivery of x-ray fluence patterns that vary in intensity both across a single projection image (u,v) and for different projection view angles (θ) and provide the ability to perform intensity-modulated cone-beam CT. Implementation of an intensity-modulated cone-beam CT system for task-specific imaging has potential for tremendous reductions in patient dose and x-ray scatter reaching the detector. Pursuing this advanced imaging technique requires detailed characterization of the cone-beam CT platform. Determination of appropriately modulated fluence patterns relies on knowledge of numerous properties of the imaging system, including the constraints imposed by the modulator, the magnitude of x-ray scatter under different patient sizes and modulator positions, and properties of the detector. With an estimate of the patient anatomy and knowledge of the imaging system, an iterative process can be used to determine modulated fluence patterns corresponding to an image prescribed for the specific task and patient. Delivery of such modulated fluence patterns provide a CBCT image tailored to a specific patient and imaging task offering the optimum balance between image quality and patient dose. Specifically, arbitrary regions of interest requiring high image signal-to-noise ratio can be generated through knowledgeable spatio-angular intensity modulation, allowing image quality to degrade in other regions in order to minimize x-ray scatter and imaging dose.

© (2007) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

S. A. Graham ; J. H. Siewerdsen and D. A. Jaffray
"Intensity-modulated fluence patterns for task-specific imaging in cone-beam CT", Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 651003 (March 13, 2007); doi:10.1117/12.713724; http://dx.doi.org/10.1117/12.713724


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.