Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Development of a critical-angle transmission grating spectrometer for the International X-Ray Observatory

[+] Author Affiliations
Ralf K. Heilmann, Minseung Ahn, Marshall W. Bautz, Richard Foster, David P. Huenemoerder, Herman L. Marshall, Pran Mukherjee, Mark L. Schattenburg, Norbert S. Schulz, Matthew Smith

Massachusetts Institute of Technology (USA)

Proc. SPIE 7437, Optics for EUV, X-Ray, and Gamma-Ray Astronomy IV, 74370G (August 31, 2009); doi:10.1117/12.825394
Text Size: A A A
From Conference Volume 7437

  • Optics for EUV, X-Ray, and Gamma-Ray Astronomy IV
  • Stephen L. O'Dell; Giovanni Pareschi
  • San Diego, CA | August 02, 2009

abstract

We present a high-resolution soft x-ray grating spectrometer concept for the International X-Ray Observatory (IXO) that meets or exceeds the minimum requirements for effective area (> 1, 000 cm2 for E < 1 keV) and spectral resolution (E/▵E > 3, 000). At the heart of the spectrometer is an array of recently developed highefficiency blazed transmission gratings, the so-called critical-angle transmission (CAT) gratings. They combine the advantages of traditional transmission gratings (very low mass, extremely relaxed alignment and flatness tolerances) with those of x-ray reflection gratings (high efficiency due to blazing in the direction of grazing-incidence reflection). In addition, a CAT grating spectrometer is well-suited for co-existence with energy-dispersive highenergy focal plane detectors, since most high-energy x rays are neither absorbed, nor diffracted, and contribute to the effective area at the telescope focus. Since our initial successful x-ray demonstrations of the CAT grating concept with large-period and lower aspect-ratio prototypes, we have now microfabricated 200 nm-period silicon CAT gratings comprised of grating bars with the required dimensions (6 micron tall, 40 nm wide, aspect ratio 150), optimized for the 0.3 to 1.0 keV energy band. Preliminary analysis of recent x-ray tests show blazing behavior up to 1.28 keV in accordance with predictions.

© (2009) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Ralf K. Heilmann ; Minseung Ahn ; Marshall W. Bautz ; Richard Foster ; David P. Huenemoerder, et al.
"Development of a critical-angle transmission grating spectrometer for the International X-Ray Observatory", Proc. SPIE 7437, Optics for EUV, X-Ray, and Gamma-Ray Astronomy IV, 74370G (August 31, 2009); doi:10.1117/12.825394; http://dx.doi.org/10.1117/12.825394


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.