0

Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Quantitative comparison of wavelength dependence on penetration depth and imaging contrast for ultrahigh-resolution optical coherence tomography using supercontinuum sources at five wavelength regions

[+] Author Affiliations
S. Ishida, N. Nishizawa

Nagoya Univ. (Japan)

Proc. SPIE 8213, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XVI, 821330 (February 9, 2012); doi:10.1117/12.907996
Text Size: A A A
From Conference Volume 8213

  • Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XVI
  • Joseph A. Izatt; James G. Fujimoto; Valery V. Tuchin
  • San Francisco, California, USA | January 21, 2012

abstract

Optical coherence tomography (OCT) is a non invasive optical imaging technology for micron-scale cross-sectional imaging of biological tissue and materials. We have been investigating ultrahigh resolution optical coherence tomography (UHR-OCT) using fiber based supercontinuum sources. Although ultrahigh longitudinal resolution was achieved in several center wavelength regions, its low penetration depth is a serious limitation for other applications. To realize ultrahigh resolution and deep penetration depth simultaneously, it is necessary to choose the proper wavelength to maximize the light penetration and enhance the image contrast at deeper depths. Recently, we have demonstrated the wavelength dependence of penetration depth and imaging contrast for ultrahigh resolution OCT at 0.8 μm, 1.3 μm, and 1.7 μm wavelength ranges. In this paper, additionally we used SC sources at 1.06 μm and 1.55 μm, and we have investigated the wavelength dependence of UHR-OCT at five wavelength regions. The image contrast and penetration depth have been discussed in terms of the scattering coefficient and water absorption of samples. Almost the same optical characteristics in longitudinal and lateral resolution, sensitivity, and incident optical power at all wavelength regions were demonstrated. We confirmed the enhancement of image contrast and decreased ambiguity of deeper epithelioid structure at longer wavelength region.

© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

S. Ishida and N. Nishizawa
"Quantitative comparison of wavelength dependence on penetration depth and imaging contrast for ultrahigh-resolution optical coherence tomography using supercontinuum sources at five wavelength regions", Proc. SPIE 8213, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XVI, 821330 (February 9, 2012); doi:10.1117/12.907996; http://dx.doi.org/10.1117/12.907996


Access This Article
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
 
Sign In to Access Full Content

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
Buy this article ($18 for members, $25 for non-members).
Sign In