Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Calibration and data quality of warm IRAC

[+] Author Affiliations
S. J. Carey, J. A. Surace, W. J. Glaccum, J. Ingalls, J. Krick, P. Lowrance, S. Laine, J. O'Linger, J. R. Stauffer

Spitzer Science Ctr., California Institute of Technology (USA)

M. Lacy

Spitzer Science Ctr., California Institute of Technology (USA) and National Radio Astronomy Observatory (USA)

S. P. Willner, J. L. Hora, M. L. N. Ashby, J.-S. Huang, M. Pahre, Z. Wang, G. G. Fazio

Harvard-Smithsonian Ctr. for Astrophysics (USA)

W. F. Hoffmann

Steward Observatory, The Univ. of Arizona (USA)

M. Marengo

Harvard-Smithsonian Ctr. for Astrophysics (USA) and Iowa State Univ. (USA)

M. Werner

Jet Propulsion Lab. (USA)

Proc. SPIE 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wave, 77310N (August 04, 2010); doi:10.1117/12.857788
Text Size: A A A
From Conference Volume 7731

  • Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wave
  • Jacobus M. Oschmann, Jr.; Mark C. Clampin; Howard A. MacEwen
  • San Diego, California, USA | June 27, 2010

abstract

We present an overview of the calibration and properties of data from the IRAC instrument aboard the Spitzer Space Telescope taken after the depletion of cryogen. The cryogen depleted on 15 May 2009, and shortly afterward a two-month- long calibration and characterization campaign was conducted. The array temperature and bias setpoints were revised on 19 September 2009 to take advantage of lower than expected power dissipation by the instrument and to improve sensitivity. The final operating temperature of the arrays is 28.7 K, the applied bias across each detector is 500 mV and the equilibrium temperature of the instrument chamber is 27.55 K. The final sensitivities are essentially the same as the cryogenic mission with the 3.6 μm array being slightly less sensitive (10%) and the 4.5 μm array within 5% of the cryogenic sensitivity. The current absolute photometric uncertainties are 4% at 3.6 and 4.5 μm, and better than milli-mag photometry is achievable for long-stare photometric observations. With continued analysis, we expect the absolute calibration to improve to the cryogenic value of 3%. Warm IRAC operations fully support all science that was conducted in the cryogenic mission and all currently planned warm science projects (including Exploration Science programs). We expect that IRAC will continue to make ground-breaking discoveries in star formation, the nature of the early universe, and in our understanding of the properties of exoplanets.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

S. J. Carey ; J. A. Surace ; W. J. Glaccum ; J. Ingalls ; J. Krick, et al.
"Calibration and data quality of warm IRAC", Proc. SPIE 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wave, 77310N (August 04, 2010); doi:10.1117/12.857788; http://dx.doi.org/10.1117/12.857788


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.