abstract

The aim of the study was to investigate the thermal effects of the 1940-nm Tm-fiber laser on the dead brain tissue. 4-5 mm coronal sections were taken from lamb brains. Tm-fiber laser was applied at the back (cortical) and below the cortex (subcortical) of these slices with 0.5 mm distance. At the beginning of the research in order to find appropriate laser parameter to be compared for 1940-nm Tm-fiber laser, the carbonization and coagulation times of the brain slices were recorded for each power value, both for cortical and subcortical tissue. The appropriate laser parameters for lamb brain tissue were selected according to this study. Lasers were applied in both continuous and pulsed modes. In continuous mode, doses were changed with fixed application time. In pulsed mode, doses were modified with the change in pulse width. The lesions were detected with microscope. The radius of ablation and coagulation for each laser application was recorded. By calculating ablation efficiency (100xablation/calculation radius) the aproppriate laser doses were determined for both cortical and subcortical tissue. The maximum ablation efficiency for cortical tissue in continuous mode was 200 mW and 600 mW and in pulsed mode was 600 mW and for subcortical tissue maximum ablation efficiency was found 600 mW in both continuous mode and pulsed mode.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Burcu Tunç and Murat Gülsoy
"Removal of brain tissue by 1940-nm Tm-Fiber laser", Proc. SPIE 7901, Energy-based Treatment of Tissue and Assessment VI, 79010L (February 22, 2011); doi:10.1117/12.875200; http://dx.doi.org/10.1117/12.875200


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.