Image noise sensitivity of dual-energy digital mammography for calcification imaging

[+] Author Affiliations
Xi Chen, Xuanqin Mou

Xi'an Jiaotong Univ. (China)

Robert M. Nishikawa

The Univ. of Chicago (USA)

Suk-tak Chan, Lei Zhang

The Hong Kong Polytechnic Univ. (Hong Kong, China)

Proc. SPIE 7961, Medical Imaging 2011: Physics of Medical Imaging, 796155 (March 16, 2011); doi:10.1117/12.877932
Text Size: A A A
From Conference Volume 7961

  • Medical Imaging 2011: Physics of Medical Imaging
  • Norbert J. Pelc; Ehsan Samei; Robert M. Nishikawa
  • Lake Buena Vista, Florida | February 12, 2011

abstract

Dual-energy digital mammography (DEDM) can suppress the contrast between adipose and glandular tissues and generate dual-energy (DE) calcification signals. DE calcification signals are always influenced by many factors. Image noise is one of these factors. In this paper, the sensitivity of DE calcification signal to image noise was analyzed based on DEDM physical model. Image noise levels of two different commercially available digital mammography systems, GE Senographe Essential system and GE Senographe DS system, were measured. The mean noise was about 1.04% for Senographe Essential system, 1.42% for Senographe DS system at 28kVp/50mAs; and was 0.47% for Senographe Essential system, 0.79% for Senographe DS system at 48kVp/12.5mAs. Evaluations were performed by comparing RMS (Root-Mean-Square) of calcification signal fluctuations in background regions and CNR (Contrast-Noise-Ratio) of calcification signals in clusters when these two digital mammography systems were used. The results showed that image noise had a serious impact on DEDM calcification signals. If GE Senographe Essential system was used, calcification signal fluctuations were 200~300μm, and when calcification size is greater than 300μm, the probability of acquiring CNR≥3 is over 50%. If noise reduction techniques are used, the calcification threshold size of CNR≥3 can be lower.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Xi Chen ; Robert M. Nishikawa ; Suk-tak Chan ; Lei Zhang and Xuanqin Mou
"Image noise sensitivity of dual-energy digital mammography for calcification imaging", Proc. SPIE 7961, Medical Imaging 2011: Physics of Medical Imaging, 796155 (March 16, 2011); doi:10.1117/12.877932; http://dx.doi.org/10.1117/12.877932


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.