A novel hyper-elastic thin film nitinol covered stent significantly decreases intra-aneurysmal flow in vitro

[+] Author Affiliations
Youngjae Chun, Soojung C. Hur, K. P. Mohanchandra, Dino Di Carlo, Gregory P. Carman

Univ. of California, Los Angeles (USA)

Colin P. Kealey

David Geffen School of Medicine at UCLA (USA)

Daniel S. Levi

Mattel Children's Hospital UCLA (USA)

Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 79840V (March 31, 2011); doi:10.1117/12.880609
Text Size: A A A
From Conference Volume 7984

  • Health Monitoring of Structural and Biological Systems 2011
  • Tribikram Kundu
  • San Diego, California, USA | March 06, 2011

abstract

A novel hyper-elastic thin film nitinol (HE-TFN) covered stent has been developed to promote aneurysm quiescence by diminishing flow across the aneurysm's neck. Laboratory aneurysm models were used to assess the flow changes produced by stents covered with different patterns of HE-TFN. The flow diverters were constructed by covering Wingspan stents (Boston Scientific) with HE-TFNs (i.e., 82 and 77% porosity) and deployed in both in vitro wide-neck and fusiform glass aneurysm models. In wide-neck aneurysms, the 82% porous HE-TFN stent reduced mean flow velocity in the middle of the sac by 86.42±0.5%, while a 77% porous stent reduced the velocity by 93.44±4.99% (n=3). Local wall shear rates were also significantly reduced by about 98% in this model after device placement. Tests conducted on the fusiform aneurysm revealed smaller intra-aneurysmal flow velocity reduction to 48.96±2.9% for 82% porous and to 59.2±6.9% for 77% porous stent, respectively. The wall shear was reduced by approximately 50% by HE-TFN stents in fusiform models. These results suggest that HE-TFN covered stents have potential to promote thrombosis in both wide-necked and fusiform aneurysm sacs.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Topics

Thin films ; Neck ; Glasses
Citation

Youngjae Chun ; Soojung C. Hur ; Colin P. Kealey ; Daniel S. Levi ; K. P. Mohanchandra, et al.
"A novel hyper-elastic thin film nitinol covered stent significantly decreases intra-aneurysmal flow in vitro", Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 79840V (March 31, 2011); doi:10.1117/12.880609; http://dx.doi.org/10.1117/12.880609


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.