Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

On-orbit radiometric calibration of Earth-observing sensors using the Radiometric Calibration Test Site (RadCaTS)

[+] Author Affiliations
Jeffrey S. Czapla-Myers, Nathan P. Leisso, Nikolaus J. Anderson, Stuart F. Biggar

College of Optical Sciences, The Univ. of Arizona (United States)

Proc. SPIE 8390, Algorithms and Technologies for Multispectral, Hyperspectral, and Ultraspectral Imagery XVIII, 83902B (May 8, 2012); doi:10.1117/12.918614
Text Size: A A A
From Conference Volume 8390

  • Algorithms and Technologies for Multispectral, Hyperspectral, and Ultraspectral Imagery XVIII
  • Sylvia S. Shen; Paul E. Lewis
  • Baltimore, Maryland, USA | April 23, 2012

abstract

Vicarious techniques are used to provide supplemental radiometric calibration data for sensors with onboard calibration systems, and are increasingly important for sensors without onboard calibration systems. The Radiometric Calibration Test Site (RadCaTS) is located at Railroad Valley, Nevada. It is a facility that was developed with the goal of increasing the amount of ground-based radiometric calibration data that are collected annually while maintaining the current level of radiometric accuracy produced by traditional manned field campaigns. RadCaTS is based on the reflectance-based approach, and currently consists of a Cimel sun photometer to measure the atmosphere, a weather station to monitor meteorological conditions, and ground-viewing radiometers (GVRs) that are used the determine the surface reflectance throughout the 1 × 1-km area. The data from these instruments are used in MODTRAN5 to determine the at-sensor spectral radiance at the time of overpass. This work describes the RadCaTS concept, the instruments used to obtain the data, and the processing method used to determine the surface reflectance and top-of-atmosphere spectral radiance. A discussion on the design and calibration of three new eight-channel GVRs is introduced, and the surface reflectance retrievals are compared to in situ measurements. Radiometric calibration results determined using RadCaTS are compared to Landsat 7 ETM+, MODIS, and MISR. © (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Jeffrey S. Czapla-Myers ; Nathan P. Leisso ; Nikolaus J. Anderson and Stuart F. Biggar
" On-orbit radiometric calibration of Earth-observing sensors using the Radiometric Calibration Test Site (RadCaTS) ", Proc. SPIE 8390, Algorithms and Technologies for Multispectral, Hyperspectral, and Ultraspectral Imagery XVIII, 83902B (May 8, 2012); doi:10.1117/12.918614; http://dx.doi.org/10.1117/12.918614


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.