Paper
15 October 2012 Fast scan-fail device for class 1 operation of scanning micromirrors at a high laser power in the near-infrared region
S. Bogatscher, C. Giesel, T. Beuth, H. Umesh-Babu, L. Shinohara, N. Heussner, A. Streck, W. Stork
Author Affiliations +
Abstract
With the availability and maturity of scanning micromirrors, a growing field of applications other than picoprojectors is emerging. The miniaturization potential of these scan based setups is most attractive for robotic vision and LIDAR imaging sensors for autonomous guided vehicles. The laser safety concept of picoprojectors is based on the eye blink reflex and high scanning frequencies (<10 kHz). However, in remote sensing applications, where infrared wavelengths and very often lower scanning frequencies are a common choice, there is a demand for robust scan failure detection. According to IEC 60825 the maximum emission time of a 100 mW CW Laser at 900 nm must be below 5 μs to be classified as a class 1 laser source. State-of-the-art scan-fail devices, which are designed for laser light shows, only feature reaction times down to 1 ms. Therefore, to enable class 1 operation of a laser scanner, based on micromirrors, a detailed examination of all possible failure scenarios was performed and consequently a fast scan-fail device with a reaction time of less than 5 μs was developed. The position of the micromirror is measured optically by focusing a laser diode to the micromirror and detecting the mirror position with a quadrant photodiode. To determine the current angular velocity of the micromirror the first derivative of the position signal is evaluated and monitored. This enables the eyesafe use of reasonably powered infrared lasers in low-cost scanning setups.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S. Bogatscher, C. Giesel, T. Beuth, H. Umesh-Babu, L. Shinohara, N. Heussner, A. Streck, and W. Stork "Fast scan-fail device for class 1 operation of scanning micromirrors at a high laser power in the near-infrared region", Proc. SPIE 8512, Infrared Sensors, Devices, and Applications II, 85120E (15 October 2012); https://doi.org/10.1117/12.929717
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Micromirrors

Failure analysis

Laser safety

Photodiodes

Safety

Laser development

Pico projectors

RELATED CONTENT

Mobile laser cutting system for complex rescue operations
Proceedings of SPIE (February 15 2018)
From lab to life engineering concepts in the design...
Proceedings of SPIE (October 22 2001)
Specific Performance Requirements For Laser Products
Proceedings of SPIE (January 26 1979)
High-power laser diodes safety operation area
Proceedings of SPIE (October 03 2006)
GMPLS control plane failure recovery
Proceedings of SPIE (November 19 2008)

Back to Top