Abstract
The application of industrial CT covers many orders of magnitude of object sizes, ranging from freight containers (few meters) down to liquid foams (i.e. for food industry) or even parts of insects which are only several hundreds of micrometers in size. Similarly, the specifications for acquisition speed extend over some orders of magnitude, from hours to sub-second CT. We present the current technology in terms of X-ray sources and detectors, along with numerous applications from industry and materials research: e.g. industrial high-speed CT of car pistons, in situ micro-CT of milk foam decay at micrometer spatial resolution and 8 s scan time, as well as ex situ scans of tensile tested Nickel-alloys. The Fraunhofer Development Center X-ray Technology (Fürth, Germany) and the Chair of X-ray Microscopy (University Würzburg, Germany) are currently working on extending the technological limits, demonstrated, e,g. by the development of advanced X-ray detectors or a new inhouse CT system which comprises a high-brilliance liquid metal jet anode.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S. Zabler, C. Fella, A. Dietrich, F. Nachtrab, Michael Salamon, V. Voland, T. Ebensperger, S. Oeckl, R. Hanke, and N. Uhlmann "High-resolution and high-speed CT in industry and research", Proc. SPIE 8506, Developments in X-Ray Tomography VIII, 850617 (17 October 2012); https://doi.org/10.1117/12.964588
Lens.org Logo
CITATIONS
Cited by 16 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Liquids

X-ray computed tomography

Foam

X-ray detectors

Metals

RELATED CONTENT

Soil matrix study using a hybrid a Se CMOS pixel...
Proceedings of SPIE (October 17 2022)
Investigation of low dose energy dispersive x ray computed...
Proceedings of SPIE (September 09 2019)
Seventh-generation CT
Proceedings of SPIE (March 31 2016)
High speed dual energy x ray photon counter Using a...
Proceedings of SPIE (January 28 2019)
Evaluation of x ray detectors for dual modality CT SPECT...
Proceedings of SPIE (November 26 2002)
X ray tube based phase CT spectrum polychromatics and...
Proceedings of SPIE (March 16 2011)

Back to Top