Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Practical considerations for intensity modulated CT

[+] Author Affiliations
Timothy P. Szczykutowicz, Charles Mistretta

Univ. of Wisconsin-Madison (United States)

Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83134E (February 23, 2012); doi:10.1117/12.911355
Text Size: A A A
From Conference Volume 8313

  • Medical Imaging 2012: Physics of Medical Imaging
  • Norbert J. Pelc; Robert M. Nishikawa; Bruce R. Whiting
  • San Diego, California, USA | February 04, 2012

abstract

As most patients, for a given projection, contain regions of vastly different attenuation properties, the dose level is often far higher than is required for some regions and inadequate for others. In this paper, two practical issues pertaining to intensity modulated CT (IMCT) are demonstrated and their causes are theoretically derived. IMCT can be enabled using a number of various techniques. The use of a system of attenuating wedges, or dynamic beam attenuators (DBA) is considered here. The first practical issue is the presence of scatter radiation. It is shown that scatter radiation produces ring artifacts due to a mismatch in the frequency of the scatter and the DBA attenuation in the CT normalization procedure. The second practical issue concerns the generation of a uniform CNR image under different scanning geometries. It is shown that when the fluence incident on the detector is equalized, different system geometries propagate the noise differently (i.e. uniform noise projections do not correspond to uniform noise images for all scanning geometries). It is also shown that a simple data re-binning procedure (re-binning from one system geometry to another) can effectively mitigate this effect and allow for uniform noise images. In addition, a method to estimate the scatter signal is purposed that relies on assuming the scatter signal is equal on each side of individual DBA boundaries due to its low frequency nature.© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Timothy P. Szczykutowicz and Charles Mistretta
"Practical considerations for intensity modulated CT", Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83134E (February 23, 2012); doi:10.1117/12.911355; http://dx.doi.org/10.1117/12.911355


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.