0

Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Design considerations for ultrasound detectors in photoacoustic breast imaging

[+] Author Affiliations
Wenfeng Xia, Daniele Piras, Mithun K. A. Singh, Johan C. G. van Hespen, Ton G. van Leeuwen, Wiendelft Steenbergen, Srirang Manohar

Univ. of Twente (Netherlands)

Spiridon van Veldhoven, Christian Prins

Oldelft Ultrasound B.V. (Netherlands)

Proc. SPIE 8581, Photons Plus Ultrasound: Imaging and Sensing 2013, 858113 (March 4, 2013); doi:10.1117/12.2004329
Text Size: A A A
From Conference Volume 8581

  • Photons Plus Ultrasound: Imaging and Sensing 2013
  • Alexander A. Oraevsky; Lihong V. Wang
  • San Francisco, California, USA | February 02, 2013

abstract

The ultrasound detector is the heart of a photoacoustic imaging system. In photoacoustic imaging of the breast there is a requirement to detect tumors located a few centimeters deep in tissue, where the light is heavily attenuated. Thus a sensitive ultrasound transducer is of crucial importance. As the frequency content of photoacoustic waves are inversely proportional to the dimensions of the absorbing structures, and in tissue can range from hundreds of kHz to tens of MHz, a broadband ultrasound transducer is required centered on an optimum frequency. A single element piezoelectric transducer structurally consists of the active piezoelectric material, front- and back-matching layers and a backing layer. To have both high sensitivity and broad bandwidth, the materials, their acoustic characteristics and their dimensions should be carefully chosen. In this paper, we present design considerations of an ultrasound transducer for imaging the breast such as the detector sensitivity and frequency response, which guides the selection of active material, matching layers and their geometries. We iterate between simulation of detector performance and experimental characterization of functional models to arrive at an optimized implementation. For computer simulation, we use 1D KLM and 3D finite-element based models. The optimized detector has a large-aperture possessing a center frequency of 1 MHz with fractional bandwidth of more than 80%. The measured minimum detectable pressure is 0.5 Pa, which is two orders of magnitude lower than the detector used in the Twente photoacoustic mammoscope. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Wenfeng Xia ; Daniele Piras ; Mithun K. A. Singh ; Johan C. G. van Hespen ; Spiridon van Veldhoven, et al.
" Design considerations for ultrasound detectors in photoacoustic breast imaging ", Proc. SPIE 8581, Photons Plus Ultrasound: Imaging and Sensing 2013, 858113 (March 4, 2013); doi:10.1117/12.2004329; http://dx.doi.org/10.1117/12.2004329


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
 

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement

Buy this article ($18 for members, $25 for non-members).
Sign In