abstract

On an onboard cone-beam CT (CBCT) system, the poly-energetic beam generated by current commercial x-ray tubes hardens as it penetrates the object. The beam-hardening effect results in CT image artifacts of up to 100 HU, especially around dense objects (e.g. bones). We propose to insert a half-blocked beam filter between x-ray source and object, such that any ray passing through the object is filtered once from one of the opposite directions in a single full scan. The conventional data processing of dual energy imaging is then applied to obtain material decomposition as well as CT images with no beam-hardening artifacts. In this preliminary study, we demonstrate the method feasibility using computer simulations. The beam filter thickness is optimized to balance the CT number accuracy and the noise level on the reconstructed images via both analytical calculation and measurement of image noise. A calibration phantom is designed to obtain the decomposition function for energy selective imaging by projection measurements without the knowledge of x-ray spectrum and detector response. Using the optimized beam blocker and the calibration phantom, we simulate the data acquisition using scan settings of a commercial CBCT system. Our proposed approach significantly suppresses beam-hardening artifacts and reduces the image error from 65 HU to 9 HU in the selected regions of interest on a head phantom. The method also successfully decomposes bone and soft tissue, with 95% accuracy. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Xue Dong ; Tianye Niu and Lei Zhu
" Single-scan energy-selective imaging on cone-beam CT: a preliminary study ", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86682Z (March 6, 2013); doi:10.1117/12.2008027; http://dx.doi.org/10.1117/12.2008027


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.