Paper
7 October 2014 An improved apparatus of infrared videopupillography for monitoring pupil size
T. -W. Huang, M. -L. Ko, Y. Ouyang, Y. -Y. Chen, B. -S. Sone, M. Ou-Yang, J. -C. Chiou
Author Affiliations +
Abstract
The intraocular pressure (IOP) that can diagnose or track glaucoma generally because it is one of the physiology parameters that are associated with glaucoma. But IOP is not easy and consistence to be measured under different measure conditions. Besides, diabetes is associated with diabetic autonomic neuropathy (DAN). Pupil size response might provide an indirect means about neuronal pathways, so the abnormal pupil size may relate with DAN. Hence an infrared videopupillography is needed for tracking glaucoma and exploring the relation between pupil size and DAN. Our previous research proposed an infrared videopupillography to monitoring the pupil size of different light stimulus in dark room. And this portable infrared videopupillography contains a camera, a beam splitter, the visible-light LEDs for stimulating the eyes, and the infrared LEDs for lighting the eyes. It can be mounted on any eyeglass frame. But it can modulate only two dimensions, we cannot zoom in/out the eyes. Moreover, the eye diameter curves were not smooth and jagged because of the light spots, lone eyelashes, and blink. Therefore, we redesign the optical path of our device to have three dimension modulation. Then we can zoom in the eye to increase the eye resolution and to avoid the LED light spots. The light spot could be solved by defining the distance between IR LED and CCD. This device smaller volume and less prices of our previous videopupillography. We hope this new infrared videopupillography proposed in this paper can achieving early detection about autonomic neuropathy in the future.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
T. -W. Huang, M. -L. Ko, Y. Ouyang, Y. -Y. Chen, B. -S. Sone, M. Ou-Yang, and J. -C. Chiou "An improved apparatus of infrared videopupillography for monitoring pupil size", Proc. SPIE 9220, Infrared Sensors, Devices, and Applications IV, 92200T (7 October 2014); https://doi.org/10.1117/12.2062059
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Infrared radiation

Light emitting diodes

Eye

Infrared imaging

Cameras

Charge-coupled devices

Beam splitters

Back to Top