Abstract
Femtosecond laser-induced damage threshold (LIDT) measurements for different optical components are well studied for a set of laser pulse repetition rates spanning the range between 1 Hz and 1 kHz. Recent years saw the advent of high-repetition-rate femtosecond systems with relatively high pulse energy. Therefore investigation of LIDT in the MHz region is essential. We performed several comparative femtosecond LIDT measurements on typically used ultrafast optical elements with different Ti:Sapphire laser systems having substantially different pulse repetition rates (a 1 kHz regenerative amplifier and a 4.3 MHz long-cavity oscillator) and found a substantially lower MHz LIDT threshhold.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Benedek J. Nagy, Lénárd Vámos, Dániel Oszetzky, Péter Rácz, and Péter Dombi "Femtosecond damage threshold at kHz and MHz pulse repetition rates", Proc. SPIE 9237, Laser-Induced Damage in Optical Materials: 2014, 923711 (31 October 2014); https://doi.org/10.1117/12.2068233