5 March 2015 Optical coherence tomography (OCT) in laser tissue bonding of incisions in the cornea
Yishai Porat, Ilan Gabay, David Varssano, Irina Barequet, Meira Neudorfer, Mordechai Rosner, Abraham Katzir
Author Affiliations +
Abstract
Temperature controlled laser bonding of the cornea is analyzed in this paper using optical coherence tomography imaging, histological section evaluations and tensile strength measurements. The heat generated to obtain the bonding causes changes to the tissue structure, which appear as a bowl shaped lesion around the heated spot. Optical coherence tomography is established as an appropriate modality for the assessment of these lesions, using the other methods for validation. A quantitative analysis of the lesions attributes is produced, using a dedicated image processing algorithm. By means of this method we observed that the depth of the lesion is the most effective measure in estimating the extent of the tissue reaction to heat. A comparison of the measured lesion depth, produced by different heating profiles, is presented. This comparison shows a linear dependence on both the temperature and the exposure time, within the boundaries of the experiment. The bond strength was evaluated for several set temperatures (with 20 seconds heating time in each case) displaying an optimal value at 70°C. Yet if an incision was successfully bonded, it held a higher burst pressure for a higher temperature value. These findings demonstrate the plausibility of an integrated laser tissue bonding apparatus with an optical coherence tomography probe, which will provide, for the first time, a real time feedback of the tissue structural change, and indicate the bonding progress and end point.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yishai Porat, Ilan Gabay, David Varssano, Irina Barequet, Meira Neudorfer, Mordechai Rosner, and Abraham Katzir "Optical coherence tomography (OCT) in laser tissue bonding of incisions in the cornea", Proc. SPIE 9317, Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications XV, 93170M (5 March 2015); https://doi.org/10.1117/12.2182287
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical coherence tomography

Eye

Laser tissue interaction

Cornea

Tissues

Laser bonding

Temperature metrology

Back to Top