Paper
11 March 2015 Oximetry system performance assessment with POM (acetal) phantoms incorporating hemoglobin calibration standards and customized saturation levels
Hyounguk Jang, Karam Singh, Hsing-Wen Wang, T. Joshua Pfefer, Yu Chen
Author Affiliations +
Abstract
Standardized approaches for performance assessment of biophotonic devices have the potential to facilitate system development and intercomparison, clinical trial standardization, recalibration, manufacturing quality control and quality assurance during clinical use. Evaluation of devices based on near-infrared spectroscopy (NIRS) for detection of hemoglobin (Hb) content and oxygenation have often involved tissue-simulating phantoms incorporating artificial dyes or flow systems. Towards the development of simple, effective techniques for objective, quantitative evaluation of basic NIRS system performance, we have developed and evaluated two test methods. These methods are based on cuvette inserts in solid turbid phantoms for measuring commercially-available Hb oximetry standards and custom-formulated oxy/deoxy-Hb solutions. Both approaches incorporate solid acetal, or polyoxymethylene (POM), as a tissue-simulating matrix material. First, inverse-adding-doubling (IAD) based on measurements with a spectrophotometer and an integrating sphere was used to measure POM optical properties and their stability over time. Second, two fiberopticprobe- based NIRS systems were used to measure concentration change of oxy- and deoxy-Hb in standard Hb solutions and customized Hb solutions by adding yeast. Differences in system performance were likely due to differences in light source outputs and fiberoptic probe design. Our preliminary results indicate that simple phantom-based approaches based on commercially available polymers and inclusions containing Hb standards, or controlled oxygenation levels may be useful for benchtop assessment of NIRS device quality for a variety of biophotonic devices.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hyounguk Jang, Karam Singh, Hsing-Wen Wang, T. Joshua Pfefer, and Yu Chen "Oximetry system performance assessment with POM (acetal) phantoms incorporating hemoglobin calibration standards and customized saturation levels", Proc. SPIE 9315, Design and Quality for Biomedical Technologies VIII, 931503 (11 March 2015); https://doi.org/10.1117/12.2087095
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Near infrared spectroscopy

Absorbance

Tissues

Optical properties

Oximetry

Fiber optics

Spectrophotometry

Back to Top