11 March 2015 Calibration of NIRS-measured hemodynamics with best-matched hemoglobin extinction coefficients and group statics on human-blood-model data
Ting Li, Yue Zhao, Yunlong Sun, Kai Li, Wenjie Li, Chi Zhang, Junpeng Liu
Author Affiliations +
Abstract
Near-infrared spectroscopy (NIRS) has been extensively developed for in-vivo measurements of tissue vascular oxygenation, breast tumor detection, and functional brain imaging, by groups of physicists, biomedical engineers, and mathematicians. To quantify concentrations of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin (hemodynamics), extinction coefficients of hemoglobin (ε) have to be employed. However, it is still controversial what ε values should be used and relatively what calibration should be done in NIRS quantification to achieve the highest precision, although that the differences in ε values among published data resulted in ~20% variation in quantification of hemoglobin concentration is reported based a single human blood test. We collected 12 blood samples from 12 healthy people, and with each blood sample performed blood tissue model experiments. 4 teams of published extinction value widely used in NIRS fields were employed respectively in our quantification. Calibrations based least square analysis and regression between real and estimated hemodynamics for 12 subjects were performed with each team of ε values respectively. We found that: Moaveni’s ε values contributed to highest accuracy; Regression method produced quite effective calibration, and when it combined with Moaveni’s ε values, the calibration reduced the std/mean of estimation by two orders of magnitude. Thus Moaveni’s ε values are most recommended to use in NIRS quantification, especially with our calibration matrix based on regression analysis with a group of subjects’ blood sample.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ting Li, Yue Zhao, Yunlong Sun, Kai Li, Wenjie Li, Chi Zhang, and Junpeng Liu "Calibration of NIRS-measured hemodynamics with best-matched hemoglobin extinction coefficients and group statics on human-blood-model data", Proc. SPIE 9315, Design and Quality for Biomedical Technologies VIII, 931508 (11 March 2015); https://doi.org/10.1117/12.2081531
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood

Mass attenuation coefficient

Calibration

Near infrared spectroscopy

Hemodynamics

Tissue optics

Absorbance

Back to Top