Open Access Paper
24 October 2005 A modified Mach-Zehnder inferometer for the study of coherence of laser
P. K. Shukla, K. K. Sarangpani, S. Talwar, G. S. Purbia, S. V. Nakhe, H. S. Vora
Author Affiliations +
Proceedings Volume 9664, Ninth International Topical Meeting on Education and Training in Optics and Photonics; 96642G (2005) https://doi.org/10.1117/12.2207568
Event: Ninth International Topical Meeting on Education and Training in Optics and Photonics, 2005, Marseille, France
Abstract
The coherence property of the laser light is an important aspect for the understanding of the optical physics. A modified geometry of the Mach-Zehnder interferometer has been proposed for measurement of the coherence of the laser. The geometry of the mirrors has been arranged in such a way that the reversible shear interferometer and the Michelson interferometer, both the types of the interferometers are set-up in a single geometry. Using this interferometer, the spatial and the temporal coherence of the laser beam can be measured. The interferometer is simple in design and is useful in the computer assisted visual learning of the coherence at the college and university level education and teaching in optics.

Summary

The coherence property of the laser light is important in understanding of the laser/optics and its various applications in holography etc. The reversible shear interferometer1 provides the measurement of the spatial coherence and the Michelson interferometer measures the temporal coherence of the laser. The conventional young slit method for spatial coherence measurement is not suitable for large diameter laser beams and it also requires multiple measurements. In this paper, a modified geometry of Mach Zender interferometer has been reported which can be used for the spatial coherence in a single measurement as well as for the temporal coherence measurement of the laser beam. The interferometer can be easily used in the large diameter laser beams.

The schematic of the interferometer has been shown in the figure-1. Its mirror geometry is similar to the Mach Zender interferometer, the W1 and W2 are two wedges at 450 and mirror M3 is mounted on the translation stage. The incident laser beam is split at wedge W1 and recombine at wegde W2. The one part of the laser beam propagating in the path W1→M1→M2→W2 and the other beam propagating along the path W1→W2→M3→W2, both the beams combine at wedge W2. C is the compensating plate. The wavefront from the earlier path is inverted along a line of folding.

Figure 1:

Schematic of modified Mach Zender Interferometer

00087_psisdg9664_96642G_page_1_1.jpg

The inverted wavefront interfere with other wavefront along a line of folding and the fringes are obtained by the tilt of the mirrors. The visibility of the fringes across the beam diameter gives the measure of spatial coherence in one dimension in a single measurement. Initially path length via M3 is kept same as path length via M2. For the measurement of the temporal coherence, the mirror M3 is moved apart such that visually the fringes vanishes from the position of the maximum visibility. The twice of the distance of the mirror movement of M3 gives the temporal coherence. Using this interferometer, the spatial coherence and the temporal coherence of typical unstable resonator output from the Copper Vapour Laser (CVL) has been measured and also the coherence studies on the multimode He Ne laser has been carried out.

The interferogram can be captured and monitored on-line on the PC with frame grabber card and compatible image processing software. The reversible shear fringes for the CVL has been shown in the figure-2. The spatial coherence of the CVL is not good as can be visually observed from the interferogram. The spatial coherence width of the CVL (beam size ~ 45 mm) with typical uncollimated unstable resonator is approx. 8.0 mm. The temporal coherence of the Copper vapour laser has been found to be ~ 8 cm. The shear fringes of the HeNe has also been shown in the figure-3. The temporal coherence of the HeNe laser has been found to be ~ 15 cm. The HeNe has good spatial coherence across the beam diameter.The reduction in central fringe visibility from its actual value of 1.0 gives an qualitative presence of ASE (Amplified Spontaneous Emission) and also the multi mode nature of the laser beam. The interferometer can be easily set up in college optics laboratory and it will help in visual understanding and the measurement of the coherence of the laser beam.

Figure 2:

CVL fringes profile and its visibility

00087_psisdg9664_96642G_page_2_1.jpg

Figure 3:

He-Ne fringes and its Visibility Curve

00087_psisdg9664_96642G_page_2_2.jpg

Acknowledgement

The authors are grateful to S S Kushwaha, D Shukla and I Satyanarayana for providing the the support for the operation of the CVL laser syetem.

Reference

1. 

T Omatsu, K. Kuroda, T Shimura, K Chihara, M Itoh & I Ogura, Opt.Quantum.Elec., 23 S447 (1991). https://doi.org/10.1007/BF00619643 Google Scholar
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
P. K. Shukla, K. K. Sarangpani, S. Talwar, G. S. Purbia, S. V. Nakhe, and H. S. Vora "A modified Mach-Zehnder inferometer for the study of coherence of laser", Proc. SPIE 9664, Ninth International Topical Meeting on Education and Training in Optics and Photonics, 96642G (24 October 2005); https://doi.org/10.1117/12.2207568
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Interferometers

Temporal coherence

Spatial coherence

Mirrors

Visibility

Visualization

Laser applications

Back to Top