Paper
24 August 2015 A transmissive x-ray polarimeter design for hard x-ray focusing telescopes
Hong Li, Hua Feng, Jianfeng Ji, Zhi Deng, Li He, Ming Zeng, Tenglin Li, Yinong Liu, Peiying Heng, Qiong Wu, Dong Han, Yongwei Dong, Fangjun Lu, Shuangnan Zhang
Author Affiliations +
Abstract
The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 105 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hong Li, Hua Feng, Jianfeng Ji, Zhi Deng, Li He, Ming Zeng, Tenglin Li, Yinong Liu, Peiying Heng, Qiong Wu, Dong Han, Yongwei Dong, Fangjun Lu, and Shuangnan Zhang "A transmissive x-ray polarimeter design for hard x-ray focusing telescopes", Proc. SPIE 9601, UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIX, 96010V (24 August 2015); https://doi.org/10.1117/12.2185435
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Polarimetry

X-rays

Sensors

Polarization

X-ray telescopes

Modulation

X-ray astronomy

RELATED CONTENT

A possibility to extend the IXPE energy band
Proceedings of SPIE (August 31 2022)
A pixel by pixel equalization method for the x ray...
Proceedings of SPIE (August 31 2022)
Micropattern gas detector for x-ray polarimetry
Proceedings of SPIE (February 14 2003)
Design and tests of the hard x ray polarimeter X...
Proceedings of SPIE (October 24 2012)
A conceptual design of hard X ray focal plane detector...
Proceedings of SPIE (September 17 2012)

Back to Top