11 September 2015 The impact of radiation damage on photon counting with an EMCCD for the WFIRST-AFTA coronagraph
Nathan Bush, David Hall, Andrew Holland, Ross Burgon, Neil Murray, Jason Gow, Matthew Soman, Douglas Jordan, Richard Demers, Leon Harding, Michael Hoenk, Darren Michaels, Bijan Nemati, Pavani Peddada
Author Affiliations +
Abstract
WFIRST-AFTA is a 2.4m class NASA observatory designed to address a wide range of science objectives using two complementary scientific payloads. The Wide Field Instrument (WFI) offers Hubble quality imaging over a 0.28 square degree field of view, and will gather NIR statistical data on exoplanets through gravitational microlensing. The second instrument is a high contrast coronagraph that will carry out the direct imaging and spectroscopic analysis of exoplanets, providing a means to probe the structure and composition of planetary systems. The coronagraph instrument is expected to operate in low photon flux for long integration times, meaning all noise sources must be kept to a minimum. In order to satisfy the low noise requirements, the Electron Multiplication (EM)-CCD has been baselined for both the imaging and spectrograph cameras. The EMCCD was selected in comparison with other candidates because of its low effective electronic read noise at sub-electron values with appropriate multiplication gain setting. The presence of other noise sources, however, such as thermal dark signal and Clock Induced Charge (CIC), need to be characterised and mitigated. In addition, operation within a space environment will subject the device to radiation damage that will degrade the Charge Transfer Efficiency (CTE) of the device throughout the mission lifetime. Here we present our latest results from pre- and post-irradiation testing of the e2v CCD201-20 BI EMCCD sensor, baselined for the WFIRST-AFTA coronagraph instrument. A description of the detector technology is presented, alongside considerations for operation within a space environment. The results from a room temperature irradiation are discussed in context with the nominal operating requirements of AFTA-C and future work which entails a cryogenic irradiation of the CCD201-20 is presented.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nathan Bush, David Hall, Andrew Holland, Ross Burgon, Neil Murray, Jason Gow, Matthew Soman, Douglas Jordan, Richard Demers, Leon Harding, Michael Hoenk, Darren Michaels, Bijan Nemati, and Pavani Peddada "The impact of radiation damage on photon counting with an EMCCD for the WFIRST-AFTA coronagraph", Proc. SPIE 9605, Techniques and Instrumentation for Detection of Exoplanets VII, 96050E (11 September 2015); https://doi.org/10.1117/12.2189818
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electron multiplying charge coupled devices

Interference (communication)

Coronagraphy

Sensors

Signal processing

X-rays

Photon counting

Back to Top